RSU CABLE PREPARATION AND LAYING
3.3. CABLE PREPARATION ON MBM SIDE FOR RSU
For each RSU, eight lengths of 4 Pair shielded cables (4 for bus-0 and 4 for bus-1)
are required on CM side and cables in each bus are tied together as shown in fig. 3.5
(b).
3.3.1. Detail of Digital Trunk Cable (For RSU Link)
C-DOT ASSY NO. : ACB-MAXRMDXX-000
DRAWING NO. : Fig. 3.5 (a),
CABLE PART NO. : MCA-PVCTPS04-401
MCA-PVCSC013-401
CABLE MARKER NO. : M`N' `uu', M`N' `vv',
M`N' `xx', M`N' `yy'
Where N = A for Bus 0
B for Bus 1
Refer Table No. 3-4 for uu, vv, xx, yy.
CABLE DESCRIPTION : Shielded digital cable 4 pairs.
32/0.2mm black colour PVC wire.
CABLE UNIT COLOR
CODE
: GREY.
CABLE LENGTH : Site dependent (Max. of 100 m)
* Digital cable - 4x25 m. (Typical)
excluding
unsheathed section
# Ground cable - 0.3 m
SOURCE TERMINATION
PART NO.
: Wire Wrap Contact block.
MCC-BCFSW307-002
Polarised Hood 14 contact Module.
MCC-BPPOH207-401
DESTINATION
TERMINATION
PART NO.
: Digital cables - stripped wire to MDF
# Ring Terminal 2.5sq. mm/M6
MCT-ERRIN015-401
# 32/0.2 mm. PVC wire, black
(MCA-PVCSC013-401) 0.3m in length
SOURCE PLACEMENT : Frame - BTU 0/1 in CM-XL.
(Refer Table 5-1)
Slot - ESM slot
Connector - B
TAB NO. RETAINED : TAB NO. - 1 For Module 1
2 For Module 2
RSU INSTALLATION MANUAL 33