Configuration Commands
Command: +FCLASS=8 Select Voice Mode
+FCLASS=8 selects the Voice Mode. The Voice Mode commands and responses described in
this section are applicable when command +FCLASS=8. (See the Generic Modem Control
section for the definition of the FCLASS command.)
Command: +VCID Caller ID (See Caller ID +VCID on page 20)
Command: +VNH= Automatic Hang-up Control
Description: This command enables or disables automatic hangups.
Syntax: +VNH=<hook>
Defined Values: <hook> Decimal number corresponding to the selected option.
0 Modem enables automatic hangups as is normal in other modes.
1 Modem disables automatic hangups usually found in the other non-voice modes.
2 The modem disables automatic hangups in the other non-Voice Modes. The
modem performs only a “logical” hangup (returns to OK result code).
Reporting Current or Selected Values:
Command: +VNH?
Response: <hook>
Example: 0 For the default setting.
Reporting Supported Range of Parameter Values:
Command: +VNH=?
Response: (<hook> range)
Example: (0-2)
Result Codes: OK <hook> = 0-2.
ERROR Otherwise.
Command: +FLO Flow Control
Function: Select Flow Control Method
Values: 0, 1, 2, 3-255
Default:
Result Codes: OK, or ERROR
Description: The +FLO? command lets you select the method of flow control provided and used by
the modem. If +FLO=0, some other method (such as credit flow control) is used. The
Xon-Xoff method is required. Xon is the ASCII character <DC1> (11 hex). Xoff is the
ASCII character >DC3> (13 hex). CCITT V.24 circuits 106 and 133 are optional flow
control methods. If circuits 106 and 133 are not used (+FLO<>2), then circuit 106 is
held On whenever +FCLASS=8. In Voice mode, circuit 105 has no effect on the state of
transmitted data. (Circuit 133 normally reverts to use as circuit 105 (RTS) when not
used for Flow Control.)
+FLO=0 Disable Xon-Xoff and 133/105 flow control
+FLO=1 Enable Xon-Xoff flow control in either direction
+FLO=2 Enable CCITT Circuit 133 for flow control of the modem by the PC; use
CCITT Circuit 106 for flow control of the PC by the modem.
+FLO=3-255 Reserved for future standards
Vedere la pagina 36