CUSTOMATCOMMANDS
ATCommandsforHSPA‐H5Modem 162
Syntax
Command Commandtype
AT#AUTOATT=[<auto>] Set
AT#AUTOATT? Read
AT#AUTOATT=? Test
ParametersandValues
<auto>
0 DisablesGPRSauto‐attachproperty.
1 EnablesGPRSauto‐attachproperty.Default:1.
Afterthecommand#AUTOATT=1isissued—andateveryfollowingstartup—the
terminalautomaticallytriestoattachtotheGPRSservice.
MultislotClassControl#MSCLASS
Setcommandsetsthemultislotclass.
Readcommandreportsthecurrentvalueofthemultislotclassin theformat:
#MSCLASS: <class>
Testcommandreportstherangeofavailablevaluesforbothparameters<class>and<autoattach >.
Syntax
Command Commandtype
AT#MSCLASS=[<class>[,<autoattach>]] Set
AT#MSCLASS? Read
AT#MSCLASS=? Test
ParametersandValues
<class> Multislotclass.
1‐12 Class7isnotsupported.
30‐33 Default:33.
35‐38 GPRS(EGPRS)class.
<autoattach>
0 Newmultislotclassisenabledonlyatthenextdetach/attachorafterareboot.
1
Newmultislotclassisenabledimmediately,automaticallyforcingdetach/attach
procedure.
Notes
DTMmultislotclassisautomatically chosenwithmaximumallowedvalueforeveryGPRS(EGPRS)subset.
CellMonitor#MONI
#MONIisbothaSetandanExecutecommand.
Setcommandsetsonecelloutofseven,intheneighborlistoftheservingcellincludingit, fr omwhichextract