Chapter 19 – Miscellaneous Commands
Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 233
19.4 ATS5 Write Command Line Editing Character
Description: This parameter setting determines the character recognized by TA as a request to delete
the immediately preceding character from the command line.
Read Command Syntax: ATS5?
Response: <n>
OK
Write Command Syntax: ATS5=<n>
Response: OK
ERROR
Parameter Description:
<n>
Command line editing character
000....127 Default = 8