sigmadue - IEC 61131-3 Function Block Library
42
1-3-32 MONOSTABLE POSITIVE EDGE DELAY
FB Prototype
MONOSTABLE_PED
Input parameters
Output parameters
Description
This function block provides a time delay between input and output signals, as
shown in the following diagram:
Default values
Label Type Description
DI BOOL Digital input
RESET BOOL Reset input
DELAY DINT Monostable delay (ms)
Label Type Description
DOUT BOOL Digital output
DI
RESET
DELAY
BOOL
BOOL
DINT
¡
¡
¡
BOOL DOU
T
¡
Input Default values
DI FALSE
RESET FALSE
DELAY 0
Output Default values
DOUT FALSE
DI
DOUT DLY
Vedere la pagina 49